Tele vde 0435 manual
Download >> Download Tele vde 0435 manual
Read Online >> Read Online Tele vde 0435 manual
Remote setting of time delay, by external potentiometer (to be ordered separately). q Connection by screw terminals for (2) #12-16 AWG wire. Selection Guide Environment. Conforming to Standards. DIN VDE 0110, DIN EN 50022, VDE 0106 (part. 100),. VDE 0435 (part. 201), IEC 255-1-00. Approvals. CSA, GL, UL. °F. until the supply voltage is interrupted. If the supply voltage is interrupted before the interval t has expired, the output relay switches into off-position. The interval already expired is erased and is restarted when the supply volta- ge is next applied. Connections. Subject to alterations and errors www.tele-power-net.com. многофункциональное реле времени: 4 наиболее используемых функции компактная промышленная серия (ширина 22,5мм), надежные винтовые клеммы выдержка времени - от 0,05с до 10 суток (8 диапазонов) защита от непреднамеренного изменения параметров разработано и произведено в Австрии Количество функций реле времени: 2 функции (генератор импульсов). Диапазон выдержки времени: 0,05с - 10 дней (8 диапазонов). Напряжение питания: 24VAC/DC 110-240VAC. Выходной контакт: 1 переключающий, 5А/250VAC. Монтаж: на DIN-рейку. Ширина: 22,5мм. Степень защиты: IP40. Вес: 60г. Loadable parallel load: min. 1VA or 0,5W depends on the voltage (voltage B1-A2 must be. 90% of A1-A2 at a minimum). Wiring distance: capacity between A1-A2 must not exceed 10nF and resistance must not be below 1MW. Leakage current AC: approx. 2mA. (open contact at B1), min. load 0,5W/1VA. 8a System times The green supply voltage LED flashes while timing. Manual setting tool. As an accessory, a manual setting tool is available. Characteristics of C56xx range. 2 multifunction and 1 single function timer. 6 analog (0.1s-10h) or 11 .. DIN VDE 0435 part 2021. Electromagnetic compatibility. 93/68/EWG. EMC-tests acc. to tele vde 0435 timer manual datasheet, cross reference, circuit and application notes in pdf format. 5 Supply voltage. 110 - 240V AC on terminals A1 - A2. 24V AC/DC on terminals A1 - A3. (+ pole on A1 at DC-supply). Permissible voltage range: 24V AC -15% +10%. 24V DC ± 10%, 110-240V AC -15% +10%. Ripple at DC: 10% max. Frequency range: 48-63Hz. Reset time: max. 100ms. Reset voltage: > 30% of nominal Gonnections: Seties k and f: Terminals shrouded to prevent human contact, max. 4 mm2. (Series p: 8-pln socket). Series a: 11-pin socket. For standards and measurements, comp. tabulation of housings on page A1. Weight 'without plug-in power unit: approx. 280 g. Classifications: VDE 0435: dielectric strength 2000 V a.c..
Back in black pdf, Aisc 14th edition pdf, Men's health november 2017 pdf, Proto pmr 10 manual, Aap complex febrile seizure guidelines.