REINFORCEMENT DETALING FOR ISOLATED FOOTING
जॉर्डनो ג׳ורדנו ጆርዳኖ جوردانو จอร์แดโน่ JORDANO Ιορδάνοςஜார்டானோ
There are different types of foundation based on number of factors.
የተለያዩ አይነት foundation አይነቶች አሉ። Foundation የምንመርጠው የተለያዩ ምክንያቶች አሉ።
እኚ ሁሉ የምንጠቀመውን የ foundation አይነት ይወስናል።
II. This type of footing is used
1. Column is not closely spaced
👉🏿ውድ የ @Etconp ቤተሰቦች የ አንድ ህንፃ column ቢጠጋጋ ምን ችግር አለው?
👉🏿 Dear @etconp members what if the column are closely spaced?
2. Load on the footings are less
3. The safe bearing capacity of soil is generally high
The isolated footings essentially consists of a bottom slab. There are three basic types of bottom slabs are
1. Pad footing with uniform (thickness)
2. Steeped footing (with nonuniform thickness)
3. Sloped footing (trapezoidal section)

III. REINFORCEMENT DETALING OF ISOLATED FOOTING INCLUDE
1. Concrete cover of reinforcement
According to (INDIAN STANDARD) IS 456-200 the “minimum thickness to main reinforcement in footing should not be less than 50mm if footing is in contact with the earth surface directly, and 40mm for external exposed face such as surface leveling PCC. If the surface levelling is not used, then it is required to specify a cover of 75milimeteres to cover uneven surface of excavation.” PCC means plain cement concrete ሌላ ነገር አይደለም lean concrete ማለት ነው። ህንዶች RC ለማለት RCC፣ Grade beam ለማለት plinth beam ነው ሚሉት።
2. Minimum reinforcement and bar diameter
Minimum reinforcement shall not be less than 0.12 percent of the total cross sectional area.
The minimum diameter for main reinforcement should not be less than 10mm.
3. Reinforcement distribution in footing
In way RCC footing, the reinforcement is distributed uniformly across the full width of footing. In two-way square footings, the reinforcement is distributed across the full width of footing along direction. However for short direction, the reinforcement is distributed in central band as per calculation below in figure 4. The rest reinforcement in short direction is distributed equally on both sides of central band.


4. DOWEL REINFORCEMENT
Dowel reinforcement is used to tie the isolated footing from above column. With regard to dowel reinforcement development length, the development dowel bars in to column and the isolated footing shall be provided clearly shown in design drawings.

5. Lap splice
Splice length of dowel and column reinforcement shall be checked to prevent bond failure of the dowels in the footing and to prevent failure of the lap splices between the dowels and the column bars


IV. ADVANTAGE AND DISADVANTAGE OF PAD FOOTING
👉🏿 ADVANTAGE
➪ Its type of shallow foundation so it requires little excavation
➪ Can be designed to accommodate tight sights
➪ Economic due to control of foundation size
➪ Reinforcement for shear and tension can be added
➪Easy to construct
👉🏿 DISADVANTAGE
➪ Foundation size can be very large cope with high points load
➪ Limited foundation suitable to point loads of framed building
➪ Weak against different settlement that may affect the building
➪Deep excavations for foundation would require support to prevent caving in
➪Weakness against uplift force, wind forces and earthquake forces
Source:-AAiT lecture note
v. List of figure








Source: - ntpel

Source:-ntpel
Topper
AAiT
CITCIVIL.IR
BAYAN MUSTEFA