hollow metal door frame throat

hollow metal door frame throat

hollow metal door frame details cad

Hollow Metal Door Frame Throat

CLICK HERE TO CONTINUE




As your headquarters for commercial doors and frames, Premier can make what you want, in the quantity you want, in the time you need, at a cost that fits your budget.  To do so, we keep hollow steel and wood doors in stock, as well as frames that we weld to your specifications. Our assembled metal doors come gray-primed, our wood doors are ready for finishing, and all our doors can be prepped for hardware. In our shop, we also can build and install side lites and can install louvers, and hardware according to your order. As a direct distributor, Premier Door, Frame, and Hardware also handles special order commercial doors and frames.  If you need lead-lined or acoustical doors or pre-finished frames, for instance, we’ll order them for you from trusted manufacturers. Let our years of experience in the commercial door, frame, and hardware industry make your job easier.  If we can’t make what your project requires, we’ll get it for you.  We’ll also help with take-offs and keying services . . . plus fast, convenient delivery service is available to all our customers.




Activar/JL IndustriesFire extinguisher cabinets from JL Industries come in a huge variety of materials and designs – for recessed, semi-recessed, and surface-mounted installations.  The company also produces specialty models for indoor and exterior use, including the CS series, a sturdy stainless steel cabinet ideal for schools and high traffic areas, and Fire-FX Option fire-rated cabinets. Learn more at their website Larsen’s ManufacturingLarsen’s makes fire extinguisher cabinets in sizes and finishes to fit any building and complement any architectural style.  Available in stainless steel, aluminum, baked enamel, brass, and acrylic, the cabinets can be ordered with the Larsen-Loc door style option (breaking glass is not necessary for access) and the fire-rated Flame Shield option. Learn more at their websiteStock STC/SCIF Door ProgramSingle Doors sized as both 3070 and 3080 lab rated STC 50 and 52 DoorsDouble Doors sized as both 6070 and 6080 lab rated STC 50 DoorsHouston-Starr maintains custody from our warehouse to the jobsite providing the fastest lead-times in the industry.




Mid-Atlantic service area lead-times are dependent on specific job requirements and size of project.Wall Conditions The partition can be prebuilt using our split jamb frame. We are able to accommodate wall throat sizes ranging from 5” to 12”.Complete Opening Installation by Houston-Starr’s factory certified installation team allows your client to have a high quality install to ensuring your sound door assembly performs and your client can focus on their mission. Click for larger pdf image of illustrationsHardware Options AvailableLockmaster LKMsSargent and Greenleaf 2890BMortise LocksetCylindrical LocksetsRim Exit DevicesCDX-10Closers both Regular and Parallel ArmOther Hardware Applications maybe available upon special request. Click for larger pdf image of illustrationsAnchor OptionsHeavy Gauge Partition Wood StudMetal Stud (Built-in)Concrete / Masonry Click for larger pdf image of illustrationsDrywall Partition Construction Recommendations:While constructing your partition, please consider that your will door will weigh approximately 300 lbsPlease note heavy gauge stud must run from the floor to the deckPlease install wood blocking inside the steel stud to allow for the wood lag screws to anchor correctly to the partition.




Rough opening requirements:Rough Opening Width = Nominal Width of Hollow Metal Door + 3”Rough Opening Height = Nominal Height of Hollow Metal Door + 1-1/2”FlooringPlease make sure your floor is level to allow for the bottom door seal to operate correctly.This door cannot be installed on a raised floor, a partition must be built underneath the opening to support the weight of your door and frame assembly.PaintingPlease make sure that your paint is fully cured before coming in contact with the sound seals. Typically latex paints take at least 30 days to fully cure. Please check with your paint manufacturer for your specific curing time.Please make sure not to paint any of the seal or hardware on the STC door. Painting the seals will damage the gasketing and could impact your acoustical performance. Click for larger pdf image of illustrations Click for larger pdf image of illustrationsDownload Brochure Disclaimer: Houston-Starr is only providing general guidelines for construction of your partition as it relates to STC door installation.




It is the responsibility of your drywall partition installer to properly design and build your partitions. Houston-Starr accepts no responsibility for partition design, engineering or installation. All lead-times are subject to the availability of stock material.40 X-Ray Imaging Room Control Window Ray-Bar Lead Lined Telescopic Steel View Windows are own exclusive proprietary design fabricated with 16 gauge Jetcoat Hot Dipped Galvanized Steel, 1.58mm standard lead lining (Higher shielding ratings available upon request). These windows are manufactured for ease of installation in new rough opening after wallboard is installed or in existing retrofit cutout applications. Available with X-Ray Protective Lead Glass, standard 2.0+ mm lead equivalency single layer (higher lead equivalencies available upon request). And Clear Pb Lead Acrylic by, in the following lead equivalencies: 0.3 mm (1/4" Acrylic Thickness), 0.5 mm (1/2" Acrylic Thickness), 0.8 mm (3/4" Acrylic Thickness), 1.0 mm (7/8" Acrylic Thickness), 1.5 mm (1-3/8" Acrylic Thickness), and 2.0 mm (1-7/8" Acrylic Thickness).




Ray-Bar proprietary Lead Lined Telescopic View Window Frames are fabricated from l6ga. "Jetcoat" Hot Dipped Galvanized Steel (HDGS) providing a good rust resistant, paint ready surface, with 1/16" (4#) leadlining standard*. (Higher shielding value ratings available upon request) Bottom voice passage, 45 degree splayed faces (for wider view range), vertical center mullions, extra thick wall conditions, stainless steel construction (304 with #4 finish), security abuse resistant designs, special lead lining or lead glass requirements all available upon request. Our standard leadlined telescopic frames are ordered by actual glass size and fit into rough opening of 1" larger than glass size to allow 1/2" clearance around perimeter of the frame. The OUTSIDE dimensions of our standard frame are 3" Larger than glass size on X-Ray side and 4-1/4" Larger than glass size on Control Side. Example: A 12" X 12" telescopic frame will fit into a rough opening of 13 " X 13 " and will have an outside dimension of 15" on X-Ray side and 16-1/4" outside dimension on Control Side.




Separate two-piece modular telescopic view window frame and install Lead Lined/Lead Glass portion on X-Ray source side of rough opening. Install "Slip-Side" flange on control side of rough opening at same time and slide both pieces together tight to wall. Check to verify that frame is level and fasten with self-tapping pan head screws on flat flange portion to stop. Always screw through both halves of frame, 6" on center. Ray-Bar Lead Lined Vision Lite Frames are fabricated with 18 gauge cold-rolled steel with baked-on color finishes, mitred corners and internal lead lining to specified shielding requirements with x-ray safety glass permenently labeled meeting ANSI Z97.1 and CPSC 16 CFR 1201 CAT 2 for impact resistanc e requirements. Stock sizes 8x10, 10x10, 10x12, 12x12, 12x16, 16x16, 18x18, 18x24, 18x30, 18x36, 24x24, 24x30, 24x36 and 36x36 promptly available ready to ship. All other custom sizes typically available in 5 working days. These windows are available non-rated and U.L. fire-rated up to 90-minute.

Report Page