garage door motor repairs johannesburg

garage door motor repairs johannesburg

garage door motor hums

Garage Door Motor Repairs Johannesburg

CLICK HERE TO CONTINUE




The GEMINI 12V DC Domestic sliding gate system is a self contained unit, which comprise of a single 12 Volt direct current electrical motor that drives the rack pinion through a reduction gearbox. The electrical motor, carrier bearing and associated components are mounted in a rust treated base box. The base box is secured to the base plate, which in turn is cemented or bolted to a concrete base. The complete unit is enclosed with a weather resistant lid. DC Slider 7.5aHDC Slider 12aH The GEMINI 220 V sliding gate system is a self contained unit which comprise of a single 220 Volt AC electrical motor that drives the rack pinion via a gearbox. The gearbox, electrical motor and associated components are mounted in a rust treated base box. AC Slider 106Industrial Slider (Gemini Industrial) The GEMINI 12V DC swing gate system is a self contained unit, which comprise of a single 12 Volt direct current electrical motor that drives the gearbox. DC Swing MasterDC Swing Slave *




24V DC Sectional24V DC Roll-Up Single Door Roll-Up Stabilizer KitDouble Door Roll-Up Stabilizer Kit Code Hopping remote controls and receivers for high security automation. TX1 - 1 Button RemoteTX3 - 3 Button RemoteReceiver (MTQ) 12 Bit binary code compatible remote controls and receivers. TX1 - 1 Button RemoteTX3 - 3 Button RemoteRX1 - 1 Channel Self-Learning Receiver (MTQ) Safety gate beams rated up to a distance of 15 meters. 12/24V DC with open contact output on the IR-Receiver. Gemini DC Slider controller PCB. Compatible with all DC slider models. DC Slider DCS 70DC LSEDC SEDC SEL Gemini AC Slider controller PCB. Compatible with all AC slider models (EGC1, EGC2 and E2-SMT). Gemini 12V DC Swing motor PCB. Drives the master motor only or the master and slave motor. PCB AC Swing controller for master and slave. Light and lock output relays optional. PCB 12V DC Swing Contoller (DCSW2 Older Motors)PCB 12V DC Swing Contoller (DCSW5 New Motors)




AC GDO Controller PCB - Gemini 24V DC Garage Door Operator PCB with onboard receiver.24V DC GDO controller with onboard RX Module Sealed Lead Acid Batteries for DC slider, Swing and Garage Door motors. 12V 2.2aH Battery (GDO)12V 7.5aH Battery (DC Slider and Swing)12V 12aH Battery (DC Slider - Heavy Duty) GP23 12V Alkaline battery used in most remote transmitters. GP23 12V Remote Transmitter Battery AC charging transformer board used in older DC Slider and DC Swing motors. TR18 DC Transformer board 17V AC 22VA DC Charging Power Supply board used in the SEL DC Slider and new DC Swing 5 motors. Regulated 14V DC Charger Power Supply PSU-14 DC Slider motor covers made of fiber glass or UV stabilized ABS plastic. DC Slider Fiber Cover (White)DC Slider Long Fiber Cover (White)DC SEL Plastic Cover AC Slider motor covers made of fibre glass or UV stabilized ABS plastic. AC Slider Fiber CoverAC Slider Long Fiber CoverAC Slider Long Pastic Cover




Angle Iron brackets used for welding on Steel Rack. The Anti-Tamper Bracket fits over the motor cover and mounts onto the Base Plate. The Release Lever Guard covers the Red Release Lever on the SEL DC models to ensure no tampering. Galvanized metal Base Plate section to mount sliding gate motors. Includes nuts and washers. AC Slider motor anti-reverse and friction brake belt. Used on all AC slider motors. Includes tension spring and bracket. Keep belt wet with oil. AC motor starting capacitor. Replacement harness for the Garage Door Operator extrusion limit section. Roll-Up GDO Reed Switch HarnessSectional GDO Reed Switch Harness Replacement nylon, brass and aluminium gears for various Gemini products. Domestic AC Slider Nylon GearAC Garage Door Operator Nylon GearAC and DC Slider Brass and Aluminium Gears Replacement wiring harnesses for all the newer Gemini models. AC Slider Harness - All AC motors, new and old, use this replacement harness.




It excludes the limit assembly harness which is optional. AC Swing Harness – All AC Swing motors, new and old, use this replacement harness. It includes the limit switches. AC/DC Slider Limit Harness Assembly - This is a complete limit assembly harness for the AC and the DC motor complete with plug, wiring, limit switches, plastic housing and limit spring. DC Slider Harness (Normal Limit, SE and LSE models) - All newer DC motors used this replacement harness. It excludes the limit assembly harness on the normal and SE type and the pulse counter on the SE and LSE models which is optional. A new harness can be modified for old DC slider models. DC Slider Harness (SEL models) - All new SEL DC slider motors use this replacement harness. It includes the pulse counter harness but not the pulse counter board. DC Swing Harness - DC motor replacement harness. There is an old and new harness version with a master and slave motor option. Receiver Harness (RX Harness Telkom) - To connect external Universal Receivers to any Gemini gate or door controller card (PCB) with the relevant socket fitted.




AC Garage Door Opener – All the old AC GDO’s use this replacement harness. It excludes the extrusion reed switch limit assembly harness which is optional. 24V DC Garage Door Opener – This replacement harness consists of two parts. The motor harness and an extrusion reed switch assembly harness. It fits the latest models. Older models must be modified or fitted by the factory. AC/DC Slider Limit Harness Assembly – This is a complete limit assembly harness for the AC and the DC motor complete with plug, wiring, limit switches, plastic housing and limit spring. Micro switch used on all AC Slider and Swing motors and older DC Slider and Swing motors for limit and obstruction purposes. Micro Switch with Long LeverMicro Switch with Short LeverMicro Switch with No Lever Plastic PCB mount spacer used to fit controller boards (PCB’s) to the motor. 10mm Steel geared rack for all Gemini sliding motors. Comes in 2m sections and must be welded on. Limit Spring and Screw used in the limit stop assembly of most older Gemini slider motors.

Report Page