Request a Bulk Enquiry Features, Instructions To use Airbed Mattress (for Bed sores prevention) Infi TM Infi Healthcare is one of the leading air mattress suppliers, provides the product called alternating pressure air Mattress for bed sores prevention or bubble pad. We supply and export Bubble Type Anti Decubitis Air Mattress & Pump System, which has been designed for use at home, nursing home and hospitals. Superior in quality and efficiency, the equipment is light in weight that makes it very easy to transport and makes very less noise while operating. About Infi Bubble Type Air Mattress For Bed Sores Bed sores may occur, if a patient is lying on the bed for a long period of time, may be he is hospitalized, ill or disabled to walk. The reason behind the bed soars is the continuous pressure, which is applied as particular body parts along with other factors such as humidity. We offer specially designed Infi TM Air Mattress bed, which provides solution to cure or prevent bed soars.




The device is specially designed to refrain patient’s muscle from long-term fixed pressure at same position for preventing prevent bed sore. Infi Healthcare, is one of leading air bed suppliers, providing he Heavy Duty air Pump and High quality material used to make the Blue Ultra Fine mattress makes the infi air Bed a long-lasting equipment. Its durability makes it ideal not only for home use but also for Hospitals. This product is more effective in prevention of bed sores as compared to a bubble type air bed. Height of the tube is 5 inches so it allows more air and refrain of the muscles and protects the patient better. The mattress is highly durable and still u can replace the tubes when punctured. A cells and B cells are inflated by pump alternately with one cycle of 10 minutes. This innovative design is to refrain patient’s muscle from long-term fixed pressure at same position to prevent bed sore. More comfortable to the patient How to use Air Mattress For Bed Sores (Tube Type)




Place the pump of air mattress on a flat table or hang it with the help of the hanger at the foot side. Unfold & lay the air mattress on a foam mattress in a way that the connections are on the foot side. The excess ends on the leg side can be tucked under the foam mattress. On the head side excess air mattress can be used to make a pillow or can be tucked in. Connect one end of the air tubes with the air pump and the other end with the air mattress. Connect them firmly at both the ends. Make sure that air pipes are not clinked. Switch on the electric pump on the air mattress by connecting with 220-V AC. Green light will illuminate. The air mattress will start inflating. Keep the pressure adjusting Knob at full in the beginning. This will take around 10 minutes to inflate. The pump should be constantly switched on during the usage otherwise the mattress will deflate. After around 10 minutes A type bubbles will inflate rather B type will remain deflated starting the process.




Adjust pressure ideally with the adjusting Knob in such a way that there is a two fingers gap between the deflated air bubbles and the patient. To repack the mattress when not in use, you need to exhale the air out of the nozzles by pressing it from other side. Keep the electric pump of air mattress on for 23 hours and keep it off for 1 hour. Do not use the air mattress near open flame or very near to a heater. Do not smoke near the air mattress Keep sharp objects away from the air mattress. Do not stand on the air mattress. Maximum weight bearing capacity is 100 kgs therefore the attendants should not sit on the air mattress as this will cause the mattress to leak. Keep the pump of the air mattress away from water/damp surfaces. Clean the mattress with mild detergent if required. Trouble shooting : In case the pump of the air mattress does not get switched on please check the fuse at the bottom of the pump of air mattress, if burn replace with a new fuse of 1.5A/250V.




If the pump is working but the mattress is not inflating please check the connections and then check the air mattress for leakage. If found punctured use the puncture kit provided with the air mattress. Mattress Bed sore prevention system Anti Decubitis air mattresses & pump system This Mattress model’s fuse rating: FlAL250V ( ) 230V—/50Hz; Maximum weight bearing capacity 100 kg Continuous usage for 12 hours then rest time one hour Size of Mattress : Length 6.5 feet x Width 2.5 feet Mattress Bubble Size : Height 2.5 inches (approx. when inflated)What is the best chair/chair mattress to prevent bed sores?My grandmother is suffering from Stage 2 bed sores (inside her butt cheeks, right above her rectum). Her problem is that she sits in her recliner almost all day long. We get her to walk around and move as much as we can, but she's 92 years old so just a little bit of walking tires her out and she wants to sit again. I am looking at an alternating pressure mattress which seems to inflate and deflate at different times to move the pressure around while she sits.




I'd love to hear your thoughts on this and any other pressure relief chairs/chair mattresses. Also interested in any alternative solutions. We're worried about these sores worsening and getting seriously infected... Related QuestionsHow do you deal with being a family caregiver?I have found caregivers napping when my Mom's asleep. Should I be upset by this?Has anyone tried using in-home caregivers instead of placing their parent in a facility?Send To Your E-Mail Your Name Send Email for medical news and health news headlines posted throughout the day, every day. © 2004-2017 All rights reserved. MNT is the registered trade mark of MediLexicon International Limited.Some older adults become frail or ill to the point where they can’t move their bodies enough. When that happens, the skin touching their bed or chair can get irritated from constant pressure. Within days, irritated areas can develop into pressure sores (aka bedsores) because senior skin is thin and sensitive. The sores are painful and can turn into serious or life-threatening infections.




The best way to prevent pressure sores from developing is to make sure your older adult doesn’t stay in one position too long. Whether sitting or lying down, make sure they change position every 1 – 2 hours — even at night! Good ways to change position include shifting their weight, putting a pillow first under one side and then the other, or helping them to get up and move a little. Not many caregivers can move their senior every hour or two, especially during the night. That’s why it’s helpful to add a special cushion to their seat or bed for added relief. Regular cushions usually can’t relieve enough pressure, so it’s good to invest in something specially designed to prevent pressure sores. Some of these cushions are pricey because they use fancy technology to relieve pressure. Depending on how likely your senior is to get sores and how much time they spend without moving, it could really be worth the money. Serious wounds and infections aren’t cheap either!