To delete the unwanted parts of the integral trace, move the mouse pointer above the trace, right-click, then select DELETE CURRENT INTEGRAL. There are some operational differences between the two spectrometer types and between TopSpin 1. DEFINE PLOT REGION: To define a region for plotting, first display the desired region on the screen. Windows XP Introduction To Microsoft Office PowerPoint 2007. Shim your sample using Z1, Z2 and Z3 shim buttons in the BSMS display main window. Type rga to set receiver gain - wait for message telling you it is finished. NOTE: the command bsmsdisp will work on the DRX500 spectrometers also. Location: Contact: 1240 Hach Hall Steve Veysey, 1234 Hach Hall Safety All researchers working 1 HSQC and HMBC for Topspin These experiments are only possible on the 400 and 500. How to create a new dataset?

If you are using a non-standard experiment, you must also check the Bruker publication Typical Pulses for the 5mm Cryoprobe, a copy of which is in the binder, to ensure that you will not exceed the probe s power limits. Beginners Guide to CQG FX Table of Contents Logging into CQG FX. NOTE: leave spinning off for 2D experiments. Use the DISPLAY PROPERTIES menu to turn off peak labels on the display. Table Migrating to Excel 2010 - Excel - Microsoft Office 1 of 1 In This Guide Microsoft Excel 2010 looks very different, so we created this guide to help you minimize the learning curve.

As you may have already noticed, there are three Sun Microsystems SD7000 Digital Microphone Monitor Software manual Table of Contents 1. Installing The Monitor Software 1. The left mouse button will freeze the cursor in the desired location, and moving the mouse again will set an expansion region, which will become active when the left mouse button is released. We will tune the H1 coil first. If you want to change the peak picking threshold, type mi and enter a new value in the window that appears. INTEGRATION see below : Click on the integral icon above the spectrum window or type. PLOTTING: a The default method for plotting spectra is now XWinPlot TopSpinPlot. Place the spinner on the air column at the top of the magnet, and press the LIFT key again to insert the sample.

Top spin nmr manual

Click the START button to begin the shimming. The sliders are numbered, and there is a directory of numbers for the tune and match settings for most common X-nuclei hanging below the probe. NOTE: after transformation the spectrometer will automatically switch to the spectrum display window.

PHASING: Using the left mouse button, click the phasing icon on the menu to the top of the spectrum display to enter the phasing routine, or type. Beginners Guide to CQG FX Table of Contents Logging into CQG FX. In Excel columns Opening Window PowerPoint 2007 The Basics Ribbon Office Button Navigation Bar Slide View Outline View Design Area Notes Area Status Bar The Ribbon The Ribbon replaces the Menu bar that we have seen in 1 1.